EFP Technical Specifications
|
|
Position Input Signal (Selectable)
|
Standard: 4-20 mA
Split range: 4-12 mA or 12-20 mA
|
|
Electrical Power Requirements
|
18 to 30 VDC, 1 � to 3 Amps including EFP heater and transmitter
heater. 5 Amp line fuse recommended.
|
|
Pneumatic Output Pressure
|
As required by the actuator up to full supply pressure, 250 psi
maximum
|
|
Action (Selectable)
|
Direct or reverse acting
Single or double acting depending on pneumatics
|
|
Hysteresis (with Westlock Transmitter)
|
<1.0% full scale
|
|
Linearity (with Westlock Transmitter)
|
<�1.0% full scale
|
|
Repeatability (with Westlock Transmitter)
|
<�0.3% full scale
|
|
Steady State Gas Consumption
|
ZERO � See Table 2.0
|
|
Electrical Enclosure
|
Explosion Proof for Class I, Groups C and D; Class II, Groups E,
F, G; and Class III hazardous locations.
Customer interfaced electrical port: �" N.P.T. with �"
N.P.T. bushing available.
Available without enclosure for control room placement of board.
|